S0003591
Diagnostics
Deterministic checks over the selected window — every statement is computed from the data, nothing is generated.
Pass rate far below target
Pass rate is 66.35% (1,037 of 1,563 tests passed, 526 failed) against a target of 98%.
5 serial number(s) failed repeatedly
Worst unit C00000651 failed 11 times (last on 2026-08-20 07:21). Repeatedly failing units usually indicate a real hardware defect rather than a flaky test.Inspect C00000651 →
No historical comparison
Historical comparison is not available for the selected window (no tests in the equally long window before it).
Most frequent failure mode
Error 218 — "TestSW: test oscilátoru ON" occurred 173 times, 32.9% of all 526 failures in the window.
Most-failing measurement step