Deterministic checks over the selected window — every statement is computed from the data, nothing is generated.
Pass rate far below target
Pass rate is 87.94% (372 of 423 tests passed, 51 failed) against a target of 98%.
5 serial number(s) failed repeatedly
Worst unit 001943912 failed 9 times (last on 2025-10-09 06:47). Repeatedly failing units usually indicate a real hardware defect rather than a flaky test.Inspect 001943912 →
No historical comparison
Historical comparison is not available for the selected window (no tests in the equally long window before it).
Most frequent failure mode
Error 80 — "NZ3: Měření proudu: Kontrola odběru" occurred 25 times, 49% of all 51 failures in the window.
Most-failing measurement step
Measurement step 12.3 — "EL: Měření napětí LED3: (TP1/TP31)" failed 5 times across the window's 51 failed tests.