Testing Portal everyone (auth disabled)

← Portfolio

S0000601

Diagnostics

Deterministic checks over the selected window — every statement is computed from the data, nothing is generated.

Critical

Pass rate far below target

Pass rate is 84.82% (162 of 191 tests passed, 29 failed) against a target of 98%.

Warning

One failure mode dominates

Error 059 — "DMM: Kontrola hodnoty Odporu (TP2/TP3)" occurred 21 times, 72.4% of all 29 failures in the window.

Warning

One measurement step drives the failures

Measurement step 1.1 — "DMM: Kontrola hodnoty Odporu (TP2/TP3)" failed 23 times across the window's 29 failed tests.

Warning

5 serial number(s) failed repeatedly

Worst unit 002008237 failed 18 times (last on 2025-11-19 06:42). Repeatedly failing units usually indicate a real hardware defect rather than a flaky test.Inspect 002008237 →

Info

No historical comparison

Historical comparison is not available for the selected window (no tests in the equally long window before it).

Repeatedly failing units

SerialFailed testsLast failure
002008237 18 2025-11-19 06:42 Open
001876541 2 2025-11-18 09:04 Open
001876542 2 2025-11-18 09:03 Open
001876518 2 2025-11-18 09:02 Open
001876539 2 2025-11-18 09:02 Open